Heavy duty rubber sheathed cable YCW
Precautions for using YCW heavy-duty rubber sheathed cable:
1、 Equipment: A small pressure device with automatic temperature control, timing, and multiple specifications of tubular mold cavities.
2、 Rubber material: Consistent with the wire of the supplemented wire, with a higher rubber content than the supplemented material, and a slightly stronger vulcanization system.
3、 Operation method:
1. Set the temperature and time according to the vulcanization system of the rubber material;
2. Wipe the repaired area with rubber and ink thinner, especially the joint should be fully treated;
3. Cut and repair the adhesive material appropriately according to the size of the gap, taking care not to have too much or too little;
4. Insert the cut adhesive material into the gap, taking care not to exceed the circumference of the wire;
5. Wrap it with PP tape. And place it into a tubular mold cavity slightly smaller than the wire diameter, lock the upper and lower molds, and allow the pressure at the position to be filled. Note that the diameter of the mold cavity is slightly smaller than the wire diameter by 0.1~0.2mm;
6. When the vulcanization time is up, take out the product. If a small amount of rubber material overflows, use a sharp blade to clean it up and wipe it off with diluent.
4、 Verification method:
Press an appropriate amount of air into the supplied wire and place it in water. Check for any air leakage to determine its quality.